<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-22 11-44-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 49 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 64 kHz 3995 0,0250
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 4,95 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 64 kHz MIN: 17 kHz % above 76 kHz: 0,0250 Acquired: 2025/06/22 11.43.38 Total samples: 3995 Equivalent time: 0:03:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 6,1 dBr MIN: 3,0 dBr AVE: 4,95 dBr % above 12,2 dBr: 0,0 Last value: 6,0 dBr (2025/06/22 11.43.37) 11.30 11.32 11.34 11.36 11.38 11.40 11.42 0 2 4 6 Pm [dBr]